Incubator temperature setting newborn11/19/2023 ![]() ![]() TEWL and IWL-s between the 22-23 and 24-25 GW was not significantly different for infants at postnatal age. Total fluid intake (TFI), fluid output volume, TEWL, IWL-s, and electrolyte balance were compared between the two groups with controlled incubator humidity and temperature, gradually decreasing the humidity and ambient temperature from 95% to 50% and from 37.0 to 34.0 ☌, respectively, while maintaining the central body temperature at 36.5-37.5 ☌. To prevent water loss from the skin and achieve skin maturation without infection, we investigated transepidermal water loss (TEWL), IWL from the skin (IWL-s), and electrolyte balance with differences in high incubator humidity and temperature control from birth to postnatal 1 month in 22-23 GW and 24-25 GW infants.Įxtremely preterm infants born at 22-23 GW (n = 11) and 24-25 GW (n = 11), admitted to the neonatal intensive care unit between September 2018 and October 2019. Over-temperature alarm, Temperature deviation alarm, Sensor alarm, Motor fan failed alarm, Power failure alarm, Water tank position alarm, Set alarm, Check alarm, and System alarm, etc.Preterm infants, especially those born at ≤23 gestational weeks (GW), present with extremes in insensible water loss (IWL) and changes in water balance. Weighing system, Monitor shelf and Disposable skin temperature sensor, Observation lamp, SpO2, etc. Main body (including baby compartment, Base, Controller, I.V.pole and tray), Sensor box, Skin temperature sensor and Vertical height adjustment stand VHA stand), Warmer module. ☓% (Oxygen concentration setting value is 25% and above)Ĭontrol accuracy of oxygen concentration:±4%Ĭontrol Mode: Pre-warm mode, manual mode and baby mode are controlled by micro-computerīaby mode temperature control range: 32☌-37.5☌Ĭontrol accuracy (The fluctuation range between Skin temperature and Set temperature): ≤0.5☌ ☒% (Oxygen concentration setting value is 25% and below) Indication accuracy of oxygen concentration: Indication range of oxygen concentration: 0%~99%Ĭontrol range of oxygen concentration: 20%-60% Noise inside hood (stable working condition): ≤50dB(A) ![]() Inclination of the bassinet:☑2° (stepless adjustable) ≤1.0☌(mattress is on the maximum tilt position) Temperature uniformity: ≤0.8☌ (mattress is on the horizontal position) The temperature fluctuation between incubator temperature and average incubator temperature (under stable temperature condition): ≤0.5☌ Mode of control: Air mode and Baby mode controlled by micro-computerĪir temperature control range: 25☌- 37☌īaby temperature control range: 34☌ -37☌Īccuracy of skin temperature sensor: ☐.2☌ Optional Configuration: Weighing system, Observation lampĨ Inch Color LCD Infant Radiant Warmer Neonatal Incubator Self-check function with multiple failure alarm indications Stored data displayed in curve with Cartesian coordinate axis Stepless adjustable inclination of bassinet The air circulation system with outlets in both front and back of baby compartment Guide rail column in dovetail shape, easy to mount on accessories Infant Radiant Warmer Mode: Radiant Temperature Control System (Pre-warm Mode, Manual Mode, and Baby Mode), Timer īaby bassinet 360° rotatable from both sides of access doors Incubator Mode: Temperature(Air Mode, Baby Mode), Humidity and Oxygen Concentration Control System Uniform heat distribution, maintaining an optimal thermal environment for caregiver to provide immediate access to the newborn, it is ideal for use in labor and delivery rooms, NICU, and Operating Room. It is ideal for use in Infant temperature recovery, resuscitation and other occasions. For the provision of a similar maternal uterus environment for the neonate to provide stable and controlled comfortable thermal environment and servo-controlled humidity and oxygen level. ![]()
0 Comments
Leave a Reply.AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |